35 – LTI

1 February 2005

Alert 05 – 08 LTA – Floorman Struck by Snub Line

Alert 05 – 08 LTA – Floorman Struck by Snub Line WHAT HAPPENED: Operations were in progress to retrieve a storm packer set at 364’ RKB with
3 October 2004

Alert 04 – 42 Casing Running Incident Results in LTI

Alert 04 – 42 Casing Running Incident Results in LTI WHAT HAPPENED: While running 13 3/8” casing, the company man requested the fill line length to be
3 August 2004

Alert 04 – 34 H2S Inhalation: Man Fell from Tote Tank Resulting in an LTI

Alert 04 – 34 H2S Inhalation: Man Fell from Tote Tank Resulting in an LTI WHAT HAPPENED: The injured person (IP) was pumping fluid waste contents from
3 July 2004

Alert 04 – 31 Equipment Failure – Low Pressure Valve Used to Fill Casing Fails

Alert 04 – 31 Equipment Failure – Low Pressure Valve Used to Fill Casing Fails WHAT HAPPENED: The rig crew was in the process of running casing
3 June 2004

Alert 04 – 26 Fall Protection Devices

Alert 04 – 26 Fall Protection Devices WHAT HAPPENED: The oil and gas industry has recently experienced several incidents involving fall protection devices. Self Retracting Life Lines
3 May 2004

Alert 04 – 21 Crane Maintenance Results in an LTI

Alert 04 – 21 Crane Maintenance Results in an LTI WHAT HAPPENED: The mechanic and electrician were moving the generator exciter outside of the crane cab. They
3 February 2004

Alert 04 – 10 Use of Rope for Elevator Hobble Results in LTI

Alert 04 – 10 Use of Rope for Elevator Hobble Results in LTI WHAT HAPPENED: Rig crew was pulling the drilling string out of the hole to
3 February 2004

Alert 04 – 06 Repair Work Results in Eye Injury

Alert 04 – 06 Repair Work Results in Eye Injury WHAT HAPPENED: A hydraulic hose failed on an Iron Roughneck assembly. In order for the Maintenance team
3 January 2004

Alert 04 – 03 Improper Slinging Results in a Fatality & Two LTIs

Alert 04 – 03 Improper Slinging Results in a Fatality & Two LTIs WHAT HAPPENED: Using a crane the mast was lifted and attached to the rotary