13 – Running Casing

8 July 2002

Alert 02 – 30 Inattention While Pulling Slips Results in Finger Amputation

Alert 02 – 30 Inattention While Pulling Slips Results in Finger Amputation WHAT HAPPENED: When running the first joint of 9 5/8 Casing, it was decided to
8 March 2002

Alert 02 – 10 Casing Incident Results in LTI

Alert 02 – 10 Casing Incident Results in LTI WHAT HAPPENED: Recently, a casing crew was running a string of 9 5/8” casing, with the assistance of
8 January 2002

Alert 02 – 03 Near Miss – Dropped Casing Rabbit

Alert 02 – 03 Near Miss – Dropped Casing Rabbit WHAT HAPPENED: While RIH7″ liner with 5-1/2″ D.P, a 2-5/8″ rabbit was used to drift all stands
9 July 2001

Alert 01 – 26 Utility Air Hoist Incident

Alert 01 – 26 Utility Air Hoist Incident WHAT HAPPENED: Crews were using an air hoist located on the cellar deck to align a joint of 20”
9 April 2001

Alert 01 – 13 Fall From Rig Floor

Alert 01 – 13 Fall From Rig Floor WHAT HAPPENED: A drill crew was preparing to nipple down the 20″ diverter and cut off the 16″ casing.
9 February 2001

Alert 01 – 04 Side Door Collar Elevators Drops Casing Joint

Alert 01 – 04 Side Door Collar Elevators Drops Casing Joint WHAT HAPPENED: The rig crew was picking up 4-1/2 inch casing and running into the hole.
5 November 2000

Alert 00 – 33 Dropped 16″ Casing

Alert 00 – 33 Dropped 16″ Casing WHAT HAPPENED: A crew was running 16” casing using a pick-up sling and 500-ton slip type elevators. The casing threaded connections
5 October 2000

Alert 00 – 32 Stabbing Board Related Incidents

Alert 00 – 32 Stabbing Board Related Incidents WHAT HAPPENED: There have been a number of incidents where personnel have been injured when a stabbing board failed in
5 October 2000

Alert 00 – 31 Drift Dropped from Derrick

Alert 00 – 31 Drift Dropped from Derrick WHAT HAPPENED: The rig crew was drifting 4 ½” tubing while tripping in the hole. While on the board,